Leave Your Message

Motorized Liquid Cooling Ball Valve

The LIKE motorized liquid cooling ball valve pairs a stainless steel ball valve with an integrated electric actuator for remote on-off control and DCIM / BMS monitoring — automatic branch isolation across large liquid-cooled data halls without manual access.

    LIKE ValvesLiquid Cooling Valve Solutions
    www.likevalves.com
    www.likvchina.com
    Home / Valves / Liquid Cooling Valves / Motorized Liquid Cooling Ball Valve

    Motorized Liquid Cooling Ball Valve

    Remote on-off branch control with DCIM / BMS integration

    The LIKE motorized liquid cooling ball valve pairs a stainless steel ball valve with an integrated electric actuator for remote on-off control and DCIM / BMS monitoring — automatic branch isolation across large liquid-cooled data halls without manual access.

    Electric On-Off ControlRemote SwitchingDCIM IntegrationBranch Automation Retrofit
    Motorized Liquid Cooling Ball Valve
    Motorized Ball Valve — stainless steel body with integrated electric actuator

    At a Glance

    Key Specifications

    Series Motorized Ball Valve
    Bore DN15 – DN50 (1/2" – 2")
    Actuator Integrated electric actuator (on-off / modulating)
    Control Signal Dry contact on-off / 4–20 mA modulating
    Body Material CF8 (304) / CF8M (316L) stainless steel
    Typical Use Automatic cabinet branch switching / remote CDU isolation

    Note: listed specifications cover standard configurations; customization is available for specific operating conditions.

    Product Overview

    Built for Automated Liquid Cooling Duty

    The LIKE motorized liquid cooling ball valve is an electric on-off valve developed for automated liquid cooling operation. A stainless steel ball valve on a high-platform body accepts a direct-mount electric actuator and receives open/close commands from DCIM, BMS or higher-level control systems, switching cabinet branches and CDU inlets remotely. No technician access to the rack is required: open/closed feedback signals report valve status to the monitoring platform in real time, and a manual override handwheel covers power-loss operation. The full-bore, polished flow passage suits deionized water and glycol coolants — built for large, minimally staffed cooling plants running centralized control.

    Technical Data

    Technical Specifications

    Parameter Specification Remarks
    Size Range DN15 / DN20 / DN25 / DN32 / DN40 / DN50 (1/2" – 2") Other sizes on request
    Actuator On-off (ON-OFF) or modulating type Selected per control duty
    Power Supply AC220V / AC380V / DC24V Specify when ordering
    Control Signal Dry contact (on-off); 4–20 mA / 0–10 V (modulating) Open / close feedback included
    Stroke Time Approx. 15 – 30 s (full stroke, by bore size) Fast-stroke option available
    Working Pressure 0 – 2.0 MPa For higher pressure, contact us
    Temperature Range –10 °C to +150 °C Depends on seal selection
    Media Deionized water / glycol solution / synthetic coolant Corrosion-inhibited coolants

    Selection Guide

    Actuator Selection

    Type Signal & Trait Typical Duty
    ON-OFF Dry contact control with open / close feedback output Branch switching with DCIM interlock
    Modulating 4–20 mA input, continuous positioning with valve position feedback Continuous modulation with feedback
    Manual Override Handwheel operation on power loss, full open / close On-site override during power loss

    Note: actuators are IP65 as standard; IP67 and explosion-proof (Ex d IIB T4) available on request.

    Materials

    Materials & Properties

    Part Material Feature
    Body CF8 (304) / CF8M (316L) Full-bore corrosion-resistant casting
    Ball Polished stainless steel Polished bore, smooth operation
    Seat PTFE Low-torque, self-lubricating seal
    Stem Blow-out proof stainless steel Shoulder-retained under pressure
    Actuator Housing Die-cast aluminum + epoxy coating IP65 protection for plant environments
    O-ring FKM / EPDM (optional) Selected per coolant formulation

    Design

    Structural Features

    01Direct-Mount Design

    ISO 5211 direct-mount actuator on a high-platform body, delivered as a ready-to-wire assembly.

    02Remote Central Control

    Central on-off command over hundreds of branch valves via DCIM / BMS.

    03Live Position Feedback

    Open / closed feedback reports valve status to the platform in real time.

    04Power-loss Override

    Manual handwheel keeps operation available during power loss.

    05Polished Low-leach Bore

    Polished flow bore suits long-term DI water / glycol circulation.

    06Full Bore

    Full-bore passage minimizes pressure drop and pump power.

    Dimensions

    Connection & Dimension Reference

    Size Actuator End Connection Matching Pipe
    DN15 (1/2") – DN25 (1") On-off / modulating Internal thread / clamp / weld Stainless tube + fittings
    DN32 (1-1/4") – DN50 (2") On-off / modulating Flange / thread / weld Stainless tube + flanges

    Note: outline and connection dimensions are subject to factory drawings; special end connections available on request.

    Applications

    Where It Works

    Cabinet Branch Automation

    Automatic branch switching by load and patrol schedule — no manual rack access needed.

    Remote CDU Isolation

    Remotely isolate CDU inlets / outlets to shorten maintenance windows.

    Grouped Patrol Isolation

    Cycle branches in groups for coolant sampling and filter changes.

    Energy Storage & Power Electronics

    Automated cut-in / cut-off in PCS and power module cooling circuits.

    Quality

    Crafted in Detail

    Real product photos — what you see is what ships.

    Assembled valve with direct-mount electric actuator
    Assembled valve with direct-mount electric actuatorAssembled valve with direct-mount electric actuator

    Field Guide

    Installation & Maintenance

    1. 01Verify the actuator power supply, signal type and flow direction before installation, and check the flow arrow on the body against the piping.
    2. 02Leave wiring space for the actuator and dry-cycle it first to confirm end positions and feedback signals.
    3. 03During commissioning, command each valve from the platform and confirm the reported status matches the actual position.
    4. 04Avoid manual intervention while the system is pressurized; depressurize first if override is required.
    5. 05Periodically inspect actuator seals and the terminal box; keep the stem area free of coolant crystallization.

    Ordering

    How to Order

    When ordering, please specify: size (DN15 – DN50), actuator type (on-off / modulating), power supply (AC220V / AC380V / DC24V), control signal (dry contact / 4–20 mA), body material (304 / 316L), end connection (thread / clamp / flange / weld), working pressure and media. Bulk supply and pre-wired harnesses are available for projects.

    LIKE ValvesLiquid Cooling Valve Solutions

    Liquid Cooling Valves · Fluid Control Solutions for AI Data Centers
    www.likevalves.com · www.likvchina.com