Electric regulating valve installation and debugging electric regulating valve signal corresponding to the valve opening

2022-12-30
Electric regulating valve installation and debugging electric regulating valve signal corresponding to the valve opening Electric regulating valve installation and debugging Before the installation of electric control valve must carefully read the copy, the relevant power supply and must be installed by professional and technical staff. The flow direction must be in the same direction as the arrow on the valve body. The valve body shall be located above the water receiving plate of the coil to ensure that water drops into the water receiving plate. The valve body and driver must be installed in the vertical direction of 60℃ range, the above should be at least 30mm space for disassembly. Adequate maintenance maneuvering space must be maintained with nearby pipes, equipment and buildings, and must be installed where maintenance personnel can reach through inspection holes. Install the driver only after the valve body has been installed and the pipeline has passed the pressure test. If the driver has been installed on the valve body, do not apply force to the driver during installation and commissioning, otherwise the driver will be damaged. After installation and check accuracy, power debugging. At least three complete operating cycles of the driver should be observed until all components are accurate. After passing the water test, the water test will be carried out. The pressure difference between the upper and lower water of the system must be strictly controlled within 0.15MPa to ensure the effectiveness of the electric regulating valve on the water flow switch. Electric regulating valve signal corresponding to the valve opening Electric regulating valve signal corresponding to the valve opening preview: Electric regulating valve by accepting the control instrument from 4-20MA signal, to complete the control of the medium in the pipeline, flow, temperature. So how much is the valve opening corresponding to the 4-20MA current signal, and what is the conversion method? Electric regulating valve received signal and open conversion method: when the electric regulating valve to accept the current signal is less than or is 4MA when the valve is closed state. The valve opening is 6.25% when the receiving signal is 5MA. The conversion method is to subtract the 20MA signal from the 4MA closed signal, which is the 16MA open signal. The best control valve opening divided by 16MA signal opening obtained no MA open signal is 6.25%. Electric regulating valve signal corresponding to the valve opening description: That is to say, when the current signal is 8MA, the valve is opened by one quarter and the opening is 25%; When the current signal is 12MA, half of the valve is opened, and the opening degree is 50%. When the current signal is 16MA, the valve is open three-quarters, and the opening is 75%; When the current signal is 20MA, the valve is in full open state and the opening degree is 100%. The above control valve technical knowledge by Shanghai professional control valve manufacturer - Shanghai Taichen Valve Co., LTD.