V-Port Liquid Cooling Control Ball Valve
www.likvchina.com
V-Port Liquid Cooling Control Ball Valve
Equal-percentage flow control with tight shut-off
The LIKE V-port liquid cooling control ball valve uses a V-notched ball with an equal-percentage characteristic for fine branch flow trimming over a wide control range — one valve for both shut-off and modulation.
At a Glance
Key Specifications
| Series | V-Port Control Ball Valve |
| Bore | DN15 – DN50 (1/2" – 2") |
| V-Port | 30° / 60° / 90° notch options |
| Characteristic | Equal percentage (approximate) |
| Body Material | CF8 (304) / CF8M (316L) stainless steel |
| Typical Use | Branch flow trimming / cold-plate balancing |
Note: listed specifications cover standard configurations; customization is available for specific operating conditions.
Product Overview
Fine Flow Control in One Valve
The LIKE V-port control ball valve features a V-notched bore giving a near equal-percentage flow characteristic: fine control at small openings for precise branch balancing, and near full-bore capacity when wide open. Compared with an on-off ball valve, it delivers far better resolution for branch balancing and cold-plate flow allocation. The shearing action of the V-notch keeps small particles from jamming the ball, making it compatible with coolants containing corrosion inhibitors and biocides. Manual wormgear, electric or pneumatic actuation with a positioner provides closed-loop flow control.
Technical Data
Technical Specifications
| Parameter | Specification | Remarks |
|---|---|---|
| Size Range | DN15 / DN20 / DN25 / DN32 / DN40 / DN50 (1/2" – 2") | Other sizes on request |
| V-Port Angle | 30° / 60° / 90° (specified at order) | Smaller notch, finer control |
| Characteristic | Equal percentage (approximate) | Fine resolution at low openings |
| Rangeability | ≥ 100:1 | Wide control range |
| Operation | Manual wormgear / electric / pneumatic (with positioner) | Closed-loop option |
| Working Pressure | 0 – 2.0 MPa | For higher pressure, contact us |
| Temperature Range | –10 °C to +150 °C | Depends on seal selection |
| Media | Deionized water / glycol solution / synthetic coolant | Corrosion-inhibited coolants |
Selection Guide
V-Notch Selection
| Notch Angle | Flow Trait | Typical Duty |
|---|---|---|
| 30° V-Port | High resolution in small bores, fine control at low flow | Fine trimming at cold-plate ends |
| 60° V-Port | Versatile angle with a wide linear range | General branch balancing |
| 90° V-Port | High flow capacity while retaining shut-off duty | Higher-flow branches with shut-off duty |
Note: the notch angle is selected per design flow and differential pressure; Kvs calculation support is available.
Materials
Materials & Properties
| Part | Material | Feature |
|---|---|---|
| Body | CF8 (304) / CF8M (316L) | High-platform body for direct-mount actuation |
| Ball | Stainless steel V-notched ball | Precisely machined notch, consistent characteristic |
| Seat | PTFE (reinforced compounds optional) | Shearing self-cleaning action |
| Stem | Blow-out proof stainless steel | Shoulder-retained under pressure |
| Packing | PTFE braided packing / O-ring combination | Long seal life under modulation |
| Actuator | Wormgear / electric / pneumatic | Positioner for closed-loop control |
Design
Structural Features
01Equal-percentage Control
Predictable opening-to-flow mapping for accurate balancing.
02Stable at Low Opening
Smooth low-flow region prevents control hunting.
03Shearing Self-cleaning
The notch shears the media so particles will not jam the ball.
04Shut-off plus Control
Tight shutoff replaces a separate control and isolation valve pair.
05Polished Low-leach Bore
Polished flow bore suits long-term DI water / glycol circulation.
06Flexible Actuation
Manual, electric or pneumatic for any level of automation.
Dimensions
Connection & Dimension Reference
| Size | Trim | End Connection | Matching Pipe |
|---|---|---|---|
| DN15 (1/2") – DN25 (1") | 30° / 60° / 90° V-port | Internal thread / clamp / weld | Stainless tube + fittings |
| DN32 (1-1/4") – DN50 (2") | 30° / 60° / 90° V-port | Flange / thread / weld | Stainless tube + flanges |
Note: outline and connection dimensions are subject to factory drawings; special end connections available on request.
Applications
Where It Works
Branch Flow Trimming
Fine-trim branch flows to match cold-plate loads and stop maldistribution.
Cold-plate Balancing
Precise end-of-line balancing for uniform cold-plate temperatures.
CDU Manifold Regulation
Flow setting and re-trimming at manifold branch takeoffs.
Test Bench Control
Flow simulation and regulation on cooling test benches.
Quality
Crafted in Detail
Real product photos — what you see is what ships.
Field Guide
Installation & Maintenance
- 01Select the notch angle and Kvs value per design flow and pressure drop, and maintain adequate valve authority.
- 02Leave service space for the actuator and positioner, and follow the flow direction marks on the body.
- 03Calibrate opening versus flow starting from the fully closed position and record the opening-to-flow table.
- 04Install a strainer upstream to protect the seat from coarse particles.
- 05Periodically check packing compression and actuator stroke to keep modulation smooth.
Ordering
How to Order
When ordering, please specify: size (DN15 – DN50), notch angle (30° / 60° / 90°), operation (manual / electric / pneumatic), positioner if required, body material (304 / 316L), end connection, and design flow and pressure drop. Kvs sizing support is available.
Liquid Cooling Valves · Fluid Control Solutions for AI Data Centers