To ensure good workmanship around the ship pump system | impeller.net

The motor is two-thirds of the weight of the pump. Make sure there is a solid foundation under the pump. (Image source: DESMI)
John Nielsen, DESMI’s sales and application manager in China, sent a message to shipowners around the world: “Please pay attention to how your pump system is installed. Make sure it works well!”, he said. “That’s the bottom line. There are too many outfits and lack of practical experience.”
Therefore, ship owners must ensure that their field teams follow key guidelines to install the pumps correctly. John said: “Because in most cases, pump failure is not caused by pump failure.”
John Nielsen has worked at DESMI for a few years and has worked in the shipbuilding industry for more than 20 years. He knows what he is talking about. He provided the shipowner, the person in charge, the field team and the shipyard with a list of “dos and don’ts” in pump installation. He said: “You need to be aware of these things.” “The pump is just a component that will operate exactly as it was designed. However, if it is not installed correctly, you can destroy it. It’s a bit like Murphy’s law: if something goes wrong, That will definitely happen. In the end, the shipowner will have to bear the cost.”
A solid foundation A solid pump foundation is at the top of John’s list. “It is very important to complete these tasks correctly. The foundation must be supported, so there is no chance of shaking.” In other words, do not install the pump on a soft board – a steel plate with no or lack of support underneath. “There is an old shipyard saying: The same amount of steel is needed below the steel plate as the steel above it.”
If the equipment team wants to use counterweights or spring supports, they must first check the design with DESMI or a steel engineer. John said: “This is not determined by the equipment team.” “Most pumps today are vertical. Two-thirds of the pump weight is actually an electric motor. Some pumps are four and a half tons, which means that the electric motor is three tons. All this requires a very good foundation to avoid vibration and so on.”
There are standard ISO plumbing rules for pipes and valves, but due to limited space, following these rules on a ship can be tricky. John said: “So, this means you have to make another choice.” On ships, make sure that the piping design allows the liquid to flow to the suction side pump at a maximum speed of 1 meter per second (m/s). This is a rule of thumb, so you can avoid water vortex or cavitation, which will eventually damage the pump.
Then there are valve options. On ships, a large number of valves are butterfly valves, mainly because this is an inexpensive valve type. But the butterfly valve only works in the pumping direction. This is why there is always a check valve in series with the butterfly valve on the pressure side of the pump. Otherwise, if the pumps are running in parallel and one pump is dormant without a check valve installed, the active pump will instead pump liquid to the other pump-regardless of whether the butterfly valve is open or closed.
In addition, it is important that the valve must be full bore (full port). This means that when the valve is opened, it has the same diameter as the pipe. Do not use valves with a diameter slightly smaller than the pipe. This will create a small vortex inside the pipeline and eventually destroy the pipeline and valve.
Materials and Corrosion According to the liquid being pumped and the surrounding conditions, it is also important to carefully plan the pump materials used. The material choices of the pump include bronze, nickel aluminum bronze (NiAIBz), gun metal, cast iron, cast steel, stainless steel 304, stainless steel 316 and duplex stainless steel. “All these materials have their own advantages and disadvantages. It is important to consider these,” John said.
For example, DESMI usually uses 316 or duplex stainless steel for alkaline or acidic liquids. “But you must handle these materials very carefully. You need to know what you are doing. Otherwise they will corrode.”
The sea water pump designed by DESMI is usually NiALBz, and the design sea water temperature is 32°C. Sea water above this temperature becomes more corrosive. Similarly, in warm areas, cast iron is not a good choice for sea water pumps. “If you work in Greenland, the cast iron pump can last a long time, but if you work in the tropics, you can’t.”
For cryogenic fresh water pumps, DESMI design uses a cast iron casing and NiAlBz impeller, and the design water temperature is 36°C. “The problem with fresh water on board is that you need to use additives to remove oxygen to avoid corrosion/rust. But there are many different types of additives, some of which make the water very viscous, and as a result the water may leak everywhere. Additives Another problem is that these chemicals change the pH of the water. This also needs to be considered when choosing materials.”
When considering materials, pay attention to the possibility of galvanic corrosion (also called bimetallic corrosion). This phenomenon occurs when two different materials (such as copper and iron in salt water) are put together. The salt water will act as an electrolyte. John said: “This is a slow killer.” “It takes a long time to discover the problem.”
“I think many people have experienced calcium accumulation in pipes etc.-this is also due to the effect of electrochemical elements.”
John’s main advice on material selection is to carefully study the materials that should be used under different conditions and listen to expert opinions.
“We have seen many customers specify bronze. Yes, we can use bronze, but we prefer to use nickel aluminum bronze because it is more rigid. And it can better avoid electrochemical element corrosion. Therefore, this It was DESMI’s choice.”
“The last sentence in this material section is related to how to improve pump efficiency. Most pumps have an efficiency of 75-80%,” John said. “Some shipowners need 80-83%. This requires more than just an update mechanism. Although there are many ways to do this, the most common method is to coat the pump with a glass-like coating internally. An electrical control system can also be used. To improve efficiency. More and more shipowners demand higher efficiency.”
Practical issues John also made a short list of some common mistakes-practical issues that must be considered. These are small problems around the pump. Although small-but still need to consider the following:
Electrical precautions Traditional electrical installations must comply with the relevant rules and standards of the International Electrotechnical Commission (IEC), which is very important. This includes factors such as correct installation, correct cable size and correct cable temperature rating. “All this must be checked,” John Nelson said. “And in the event of a fire, you must have self-extinguishing cables. The cables must also be halogen-free. Large cables or small wires-they must all follow the same rules and regulations.”
The ground connection must be carefully made using the correct cable size. John said: “Don’t cheat.” “This means that the bottom line, the size of the ground wire must be almost the same as the main power cord. Therefore, if you are using a 3×50 mm2 power cord, you must at least use a 1x35mm2 cable for grounding. ”
A rule of thumb is to use the same wire cross section in the ground wire as the power wire of each component.
John also wants to urge consideration of where to make potential grounding. “There must be no potential electrical differences between the grounding points of the same equipment. This means that if you have a motor starter, the ground of the motor starter that drives the pump is connected to the ground of the motor. This is also called Equipotential grounding. Because if you put them 10 meters apart, you can ensure that there is a difference in potential.”
He said: “It is generally believed that just because you weld something to the steel plate, there is no difference in potential. But they are big. It’s just that the welding itself will be different.”
Molded case circuit breakers (MCCB) must be adjusted and installed correctly. The setting on the MCCB is the maximum current marked on the motor.
Set the thermal relay according to the non-overload power of the pump, which is given by the pump test table.
The inverter’s recommendations on the use of inverters and the rules and regulations follow the above-mentioned recommendations for traditional electrical installation. But you must pay extra attention, because frequency generates electrical noise that must be managed. “When installing, make sure that at least a common mode filter is installed on the inverter. Larger installations may require du/dt filters.”
You must also correctly adjust the maximum current of the frequency converter-the same as the thermal relay in a traditional starter.
Then, when you want to use the frequency converter to operate the motor, you should seriously consider increasing the temperature level of the motor to a higher temperature level. “Usually, choose F class with a temperature of 135°C.
However, when running with a frequency converter, the motor will become hot due to the switching frequency of the motor power cord. Therefore, we recommend: rise to H level, which is 150°C. This will give you more leeway. In terms of price, this is a small amount of money. ”
The cooling fan and IE2 further enable you to measure the winding temperature inside the motor as a standard configuration. This means that your motor should have a built-in PT100 sensor. Then, we can directly measure it. In addition, since this motor usually runs at a different RPM, make sure to install an electric cooling fan on the top instead of a standard mechanical fan. Because when running the motor at low RPM, you don’t have the same cooling capacity as when running at normal speed. However, if an electric fan is installed, the same amount of cooling will be obtained regardless of the speed of the load.
John Nielsen said: “When using a frequency converter, please carefully consider using a normal rated IE motor or a standard efficiency motor. The reason for this is that if the motor is connected to the frequency converter, by increasing the IE type on the motor There will be no gains. Since the aggregate efficiency of the grid will stop at the inverter, the grid efficiency on the grid is determined by the inverter. The price difference between IE2 and IE3 or IE4 is very large.”
More monitoring recommendations In addition to monitoring the winding temperature of the motor, John said: “It is worth monitoring the bearing temperature, especially on important equipment. In addition, consider monitoring the vibration level at high and low frequencies.”
“The vibration level we see is 10 millimeters per second (mm/s), which is not uncommon. The limit of the pump (if we really want to stretch) is 7 mm/s. If the vibration level is too high, it may The pump must be stopped to avoid damage to the pump or pump parts. Remember that two-thirds of the total weight of the pump is still the motor, located on top of the pump housing, bearings, etc. Therefore, if you have a three-and-a-half-ton pump motor, The literal jumping speed is 10 mm/s, which is like a huge hammer, knocking down some small bearings in some places. So – it’s only a matter of time before the pump stops on its own.”
There is also leakage monitoring. For large pumps with grease-lubricated bearings, if the shaft seal starts to leak, it will usually leak directly into the bearing. Grease and water are a bad combination. Therefore, to avoid this situation, please consider installing a leak detection sensor.
Facts have proved that after installing a new pump on Aurora, it can save +200,000 kWh per year, which is in line with ForSea’s mission, which is “committed to a sustainable, customer-centric company and strives to achieve zero emissions.
The sewage pumping station of the Sochi Olympic Park in Russia is often blocked, which brings a lot of time and resources to the municipality. Now, with the intelligent self-cleaning pump of the Xylem Flygt brand, the pumping station runs smoothly and energy consumption is reduced by 25%.
Independent testing by a large pump manufacturer proved that the non-corrosive Vesconite Hilube wear ring can safely reduce operating clearances and improve pump efficiency.
Ambitious civil engineering projects and distant accumulation of raw materials: when the work is going deep, it is not only pure pump performance that matters. Usually more important is the pH of the water.
QED Environmental Systems, Inc. focused on the AP4.5 Ultra AutoPump system, which is a low-maintenance, high-performance pump.
The application provides quick and convenient access to the DESMI Ocean Guard service and maintenance manual through simple graphical navigation to help identify and troubleshoot the CompactClean ballast water management system.


Post time: Feb-24-2021

Send your message to us:

Write your message here and send it to us
WhatsApp Online Chat !