Thermal insulation chemical pump: IR thermal insulation chemical pump product features and uses anti-corrosion chemical pump valve, filter use specification knowledge?

Thermal insulation chemical pump: IR thermal insulation chemical pump product features and uses anti-corrosion chemical pump valve, filter use specification knowledge?

/
Product overview
Type IR thermal chemical pump for single-stage single-suction cantilever centrifugal pump series, model IH chemical centrifugal pump is derived products, parts size has achieved standardized energy-efficient products, mainly used in chemical industry, chemical fiber, oil, food, pharmaceutical and other industries transport solution medium temperature (or crystallizing point) high freezing point, high temperature corrosive liquid.
Product features
IR thermal insulation chemical pump is equipped with a hollow sandwich in the main flow part, and is provided with steam, hot water, hot oil, soda and other conveying liquid and pump for multiple circulation, thermal insulation has a variety of ways to connect with the external thermal insulation system. Design pressure is 1.6Mpa, temperature: T≤250℃. Flow 3.4 ~ 460m3/h head: H=3.6 ~ 132m, speed 1450-2900r/min
Product use
IR heat preservation chemical pump is suitable for the chemical medium with solidification crystallization at room temperature, suitable for the cooling of the vaporization point of the medium, but also suitable for the alpine plateau medium temperature -80~+250℃ conveying solution medium freezing point (or crystallization point temperature) is high, with corrosion of the liquid.
Model significance
For example, IR50-32-125
Ir-thermal insulation chemical pump
50- Inlet diameter (mm)
32- Outlet caliber (mm)
Range of application
IR thermal insulation chemical pump is suitable for transporting clean or containing particles of liquid, low temperature or high temperature liquid, neutral or corrosive liquid.
Mainly used for:
Oil refinery, petrochemical industry, coal processing industry and cryogenic engineering.
Chemical industry, paper, pulp industry, sugar industry and general process industry.
Water supply plant, desalination plant
Heating and air conditioning system
Power plants
Environmental protection Project
Shipping and Marine industry, etc.
Anti-corrosion chemical pump valve, filter use specification knowledge what?
Anti-corrosion chemical pump is in the industrial production of corrosive chemical raw materials, and transport of the commonly used acid alkali liquor pump, valve is a common form a complete set of equipment, for the use of filters, basic is according to the demand of medium, usually anti-corrosion chemical pump has good corrosion resistance, the poor wear resistance, to handle more liquid solid content, can install filters, What are the specifications for valves and filters? The models, specifications and parameters of valves, filters, automatic control components and instruments shall conform to the requirements of the design documents, and technical documents such as qualification certificates and operation instructions shall be provided.

One, the globe valve, throttle valve, check valve, automatic control valve body, filter installation should meet the requirements of the design document and the current national standard “Industrial valve installation, use and maintenance general requirements” GB/T 24919, and should meet the following provisions:
1, for the packaging is intact, import and export sealing performance is good, no corrosion after inspection, no obvious defects, and in its warranty period of the valve according to the current national standard “pressure pipeline specification industry pipeline four parts: The valves that do not conform to the conditions shall be disassembled, cleaned, replaced with damaged and failed components, and shall be subjected to pressure and seal tests according to the provisions of the design documents and technical documents. The unqualified valves shall be prohibited from installation.
2. When the valve is installed in rows, the center of the valve handwheel should be on the same straight line.
3. Valves and filters that need to be installed on site for low-temperature equipment should be reserved for the thickness of the cooling layer according to the design requirements, and should not be buried in the cooling layer.
4. The installation of check valve and automatic control valve spool and filter element should be carried out after the system blowdown. When the spool cannot be disassembled or should not be disassembled according to the requirements of technical documents, measures should be taken to prevent the spool from being damaged in the process of installation and blowdown.
The influence of temperature during welding and impurities in the process of blowdown may damage the spool, so it is required to take corresponding protective measures. Valves and filters often need to be checked and maintained in the process of use. Buried in the cooling layer of the equipment will affect the implementation of these works, so it is required to reserve the thickness of the cooling layer according to the design requirements.

2. The control and actuator installation of pressure, temperature, level, flow and other automatic control components and instruments and automatic control valves shall comply with the requirements of the design document and relevant provisions of the current national standard “Code for Construction and Quality Acceptance of Automatic Instrument Engineering” GB 50093, and shall comply with the following provisions:
1. For the automatic control components and instruments with intact packaging, good sealing performance of import and export, no corrosion and obvious defects after inspection, and within the warranty period, the control and actuator of the automatic control valve can be installed directly; The automatic control components and instruments that do not meet the conditions, the control and actuator of automatic control valve shall be tested according to the relevant provisions of the current national standard “Code for Construction and Quality Acceptance of Automatic Instrument Engineering” GB 50093, and the unqualified ones shall not be installed.
2. If the equipment needs to install the liquid level gauge or liquid level sensor on site, the reference position shall be determined in strict accordance with the requirements of the design and technical documents.
3. The liquid level meter or liquid level sensor that needs to be installed on site for low-temperature equipment should be calibrated and recorded before the cooling construction.
4. The alarm device that needs to be installed on site should be checked for sensitivity before installation. For the automatic control components and instruments that need to be installed onsite, the thickness of the cooling layer should be reserved according to the design requirements, and should not be buried in the cooling layer.
If the design does not require, the installation position of the thermometer or temperature sensor in the cold room shall be free from the influence of the local heat source and cold source. Alarm device refers to the refrigeration system liquid level, temperature, pressure and other parameters of the ultra-high (**) alarm device, such as the float level controller used for ultra-high level alarm, sensitivity test refers to the simulation of alarm conditions, to check whether the alarm device can work normally. Local heat sources and cold sources include but are not limited to cold Bridges, refrigeration doors, refrigeration and hot air pipes, air cooler outlets, cold exhaust pipe surfaces, lighting fixtures, etc.
3. Pressure gauge installation shall comply with the requirements of design and technical documents and the following provisions:
1. The calibration and seal of the pressure gauge are in accordance with the relevant regulations of the supervision department of work safety. The package is in good condition, without corrosion and obvious defects.
2, ammonia refrigeration system must use ammonia pressure gauge; The protection level should not be lower than IP54.


Post time: Nov-08-2022