1. The perpendicularity of the flange surface on the pipe and the center line of the pipe and the error of the flange bolt hole should be within the range of the allowed value. Valve and piping center line should be consistent before installation.
2. When fastening bolts, use a wrench that matches the nut. When using oil pressure and pneumatic tools for fastening, pay attention not to exceed the specified torque.
3. When connecting two flanges, first of all, the flange sealing surface and gasket should be pressed evenly, so as to ensure that the flange is connected by the same bolt stress.
4. The fastening of the flange should avoid uneven force, and should be tightened in accordance with the direction of symmetry and intersection.
5. After flange installation, ensure that all bolts and nuts are fastened evenly.
6, the fastening of bolts and nuts, in order to prevent loosening caused by vibration, to use washers. In order to avoid adhesion between threads at high temperature, the thread parts should be coated with anti-adhesion agent during installation.
7. It is used for high temperature valves above 300℃. After the temperature rises, the flange connection bolts, valve cover fastening bolts, pressure seals and packing gland bolts must be tightened again.
8, low temperature valve is installed in the state of atmospheric temperature, due to the formation of temperature difference, flange, gasket, bolts and nuts shrink, and because the material of these parts is not the same
9, the respective linear expansion coefficient is also different, forming a very easy to leak environmental conditions. From this objective situation, when tightening bolts at atmospheric temperature, the torque that takes into account the contraction factors of each component at low temperature must be adopted.
1. Before installation, the inner cavity of the LPG valve should be cleaned and the defects caused in transportation should be eliminated;
2. The installation of the LPG valve should keep the butterfly valve drive shaft horizontal and the piston valve vertically upward;
3. Before using the LPG valve, the transmission device should be adjusted to keep the functions of the transmission device intact, and the limit stroke and over-torque protection control are reliable;
4. Lubricating oil should be fully added before commissioning and use of each lubricating part of the LPG valve transmission device;
5. Before starting the electric device, the manual of the electric device of the liquefied gas valve should be carefully read.